It is a high accuracy tan delta tester to test tangent value, dielectric loss and capacitance of various HV electrical equipments for transformer substations.
Share
Product Description

Transformer Tan Delta Tester Application:
 
Automatic Transformer Tangent Delta Tester is a high-precision test instrument for testing the dielectric loss tangent value and capacitance of various high-voltage power equipment on-site or in laboratories such as power plants and power substations. Measurement on dielectric loss tangent value (tgδ) and capacitance of transformer, mutual inductor, reactor, capacitor, bushing and arrester

The instrument is an integrated structure, built-in dielectric loss test bridge, variable frequency voltage regulator power supply, step-up transformer and SF6 high stability standard capacitor. The test high-voltage source is generated by the inverter inside the instrument and used for the test of the tested product after being boosted by the transformer. The frequency can be changed to 45Hz or 55Hz, 55Hz or 65Hz, and the digital notch technology is adopted to avoid the interference of power frequency electric field on the test, and fundamentally solve the problem of accurate measurement under strong electric field interference. At the same time, it is suitable for occasions where generators are used for power supply detection after all power failures.

The instrument is equipped with high-voltage boosting transformer, and has taken zero-passage closing, lightning protection and other safety protection measures. It outputs voltage of different grades ranging from 0.5kV to 10kV during test, which ensures simple and safe operation.

Features

1. LCD display, mass storage data, the instrument data can be exported through the U disk, and can generate a work report.

2. Many test modes: internal high voltage, external high voltage, internal standard, external standard, positive connection method, reverse connection method, self excitation method in a variety of ways to test; under the high pressure of outside the standard can do the high voltage of more than 10kV) dielectric loss test.
3. CVT test one-step process: to test the full sealed CVT (capacitive voltage transformer) C1, C2 dielectric loss and capacitance, to achieve the C2, C1 testing at the same. The instrument can also test the CVT ratio and voltage angle difference.
4. Multiple protections safe and reliable: with input voltage fluctuation, output short circuit, overvoltage, over current, temperature and other multiple protection measures.
5. The instrument can be used for measuring the high-voltage electrical equipment of the non grounding or grounding, and can measure the capacitance of the capacitor voltage transformer tgδ and the main capacitor C1 and C2.
6. The instrument is equipped with high voltage transformer, and takes safety protection measures against lightning, zero switching.

Technical Parameters

High voltage output: 0.5~10KV

Each files to increase 500V, a total of twenty files, capacity: 1500VA

Accuracy

tg δ: ±(reading*1.0%+0.04%)

Cx: ± (reading*1.0%+1PF)

Resolving power

tg δ: 0.01%,Cx:1pF

Measuring range

0.1%< tg δ< 100%

3PF

10KV,Cx≤30000PF

5KV, Cx≤60000PF

Power supply

AC 220V±10% ,50±1Hz

Measurement method

Power frequency: 50Hz

Pilot frequency: 45Hz/55Hz Automatic frequency conversion

Harmonic adaptation

≤ 3%

Service condition

-15℃-50℃ relative humidity<80%

Outline dimension

460(L)*345(W)*350(H)

Weight

35KG